CAUTION / NOTICE / HINT
HINT:
PROCEDURE
1. |
VEHICLE BROUGHT TO WORKSHOP |
|
2. |
CUSTOMER PROBLEM ANALYSIS |
(a) Interview the customer to confirm the trouble.
Click here
|
3. |
INSPECT BATTERY VOLTAGE |
(a) Measure the battery voltage.
Standard Voltage:
11 to 14 V
If the voltage is below 11 V, recharge or replace the battery before proceeding to the next step.
|
4. |
INSPECT COMMUNICATION FUNCTION OF CAN COMMUNICATION SYSTEM* |
(a) Using the Techstream, check if the CAN communication system is functioning normally.
Click here
Result |
Proceed to |
---|---|
CAN DTCs are not output |
A |
CAN DTCs are output |
B |
B | ![]() |
GO TO CAN COMMUNICATION SYSTEM |
|
5. |
CHECK COMBINATION METER ASSEMBLY |
(a) Check the operation of the speedometer and shift indicator on the combination meter assembly.
OK:
The speedometer and shift indicator on the combination meter assembly operate normally.
NG | ![]() |
GO TO METER / GAUGE SYSTEM |
|
6. |
PROBLEM SYMPTOMS TABLE |
(a) Refer to Problem Symptoms Table.
Click here
Result |
Proceed to |
---|---|
Fault is not listed in problem symptoms table |
A |
Fault is listed in problem symptoms table |
B |
B | ![]() |
GO TO STEP 8 |
|
7. |
OVERALL ANALYSIS AND TROUBLESHOOTING* |
(a) Data List / Active Test
Click here
(b) Terminals of ECU
Click here
(c) On-vehicle Inspection
Click here
|
8. |
REPAIR OR REPLACE |
|
9. |
CONFIRMATION TEST |
NEXT | ![]() |
END |
Toyota CH-R Service Manual > Shift Lever: Installation
INSTALLATION
PROCEDURE
1. INSTALL FLOOR SHIFT SHIFT LEVER ASSEMBLY
(a) Temporarily install the floor shift shift lever assembly to the body with
the 4 bolts.
(b) Fully tighten the 4 bolts in the order shown in the illustration.
Torque:
12 N·m {122 kgf·cm, 9 ft·lbf}
(c) Engage the 6 cl ...
Toyota CH-R Service Manual > Air Conditioning System(for Automatic Air Conditioning System With Side-mounted
Air Conditioner Pressure Sensor): Pressure Sensor Circuit (B1423)
DESCRIPTION
This DTC is stored if refrigerant pressure on the high pressure side is extremely
low (195 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPa (28.7 kgf/cm2,
408 psi) or more). The air conditioner pressure (2 words) sensor, which is installed
to the high pressure side p ...