INSPECTION
PROCEDURE
1. INSPECT PARK/NEUTRAL POSITION SWITCH
*a |
Component without harness connected (Park/Neutral Position Switch) |
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
4 (B) - 9 (L) |
Shift lever in P or N |
Below 1 Ω |
Shift lever not in P or N |
10 kΩ or higher |
|
1 (RB) - 3 (PL) |
Shift lever in P |
Below 1 Ω |
Shift lever not in P |
10 kΩ or higher |
|
1 (RB) - 2 (RL) |
Shift lever in R |
Below 1 Ω |
Shift lever not in R |
10 kΩ or higher |
|
1 (RB) - 8 (NL) |
Shift lever in N |
Below 1 Ω |
Shift lever not in N |
10 kΩ or higher |
|
1 (RB) - 7 (DL) |
Shift lever in D or M |
Below 1 Ω |
Shift lever not in D or M |
10 kΩ or higher |
If the result is not as specified, replace the park/neutral position switch.
Toyota CH-R Service Manual > Blower Unit(for Denso Made): Disassembly
DISASSEMBLY
PROCEDURE
1. PRECAUTION
NOTICE:
Make sure to perform initialization after replacing the No. 1 blower damper servo
sub-assembly. If initialization is not performed, the air conditioner unit assembly
will not perform properly as the air conditioning amplifier assembly will not be
...
Toyota CH-R Service Manual > Front Wheel Alignment: Adjustment
ADJUSTMENT
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration)
that must be performed after completing the front wheel alignment procedure are
shown below.
Necessary Procedures After Procedure Performed
Replaced Part or Perfo ...