CHECK FOR INTERMITTENT PROBLEMS
CHECK FOR INTERMITTENT PROBLEMS
HINT:
A momentary interruption (open circuit) in the connectors and/or wire harness between the sensors and ECUs can be detected using the Data List function of the Techstream.
(a) Turn the ignition switch off.
(b) Connect the Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn the Techstream on.
(e) Follow the directions on the Techstream to display the Data List and select areas where momentary interruption should be monitored.
HINT:
Tester Display |
Measurement Item |
Range |
Normal Condition |
Diagnostic Note |
---|---|---|---|---|
EFI Communication Open |
EFI communication open detection |
Error or Normal |
Error: Momentary interruption Normal: Normal |
- |
Yaw Rate Open |
Yaw rate sensor open detection |
Error or Normal |
Error: Momentary interruption Normal: Normal |
- |
Deceleration Open |
Acceleration sensor open detection |
Error or Normal |
Error: Momentary interruption Normal: Normal |
- |
Steering Open |
Steering angle sensor open detection |
Error or Normal |
Error: Momentary interruption Normal: Normal |
- |
IG Voltage Value Decreased |
+BS voltage value decrease detection |
Error or Normal |
Error: Voltage low Normal: Normal |
- |
IG Voltage Value Increased |
+BS voltage value increase detection |
Error or Normal |
Error: Voltage high Normal: Normal |
- |
(f) While observing the screen, gently jiggle the connector or wire harness between the ECU and sensors, or between ECUs.
OK:
Normal is displayed.
HINT:
If the display changes, this indicates that there has been a momentary interruption (open circuit) in the connector and/or wire harness. In this case, repair or replace the connectors and/or wire harnesses as one of them is faulty.
Toyota CH-R Service Manual > Maintenance: Back-up Light Bulb
Components
COMPONENTS
ILLUSTRATION
*1
BACK DOOR SERVICE HOLE COVER LH
*2
BACK UP LIGHT BULB
*3
BACK UP LIGHT SOCKET AND WIRE
-
-
Removal
REMOVAL
CAUTION / NOTICE / HINT
HINT:
...
Toyota CH-R Service Manual > Automatic Light Control Sensor: Removal
REMOVAL
PROCEDURE
1. REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY
Click here
2. REMOVE DEFROSTER NOZZLE ASSEMBLY
Click here
3. REMOVE AUTOMATIC LIGHT CONTROL SENSOR
(a) Disconnect the connector.
(b) Disengage the c ...